Free estimate hvac air conditioning carrier rooftop commercial Furnace Heating Repairs New Installs

Posted on May 15, 2018

Carrier rooftop systems have a standard cooling operating range up to 125 °F (52°C) and down to 35°F (-2°C). Low ambient controllers can bring cooling operation down to -20°F (-29°C)
  • Innovative non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
  • Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
  • TXV refrigerant metering device on each circuit with removable power element
  • Fully insulated cabinet
  • Carrier rooftop units control terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement
  • Access panels with easy grip handles and tool-less filter access door
  • Innovative, easy starting, no-strip screw feature on unit access panels
  • Optional hinged access panels also available
  • Carrier rooftop units have a belt drive evaporator-fan motor and pulley combinations available on all three phase models to meet any application
  • Electric Drive x13 (5 speed/torque) motor on 04 to 06 models
  • Two-inch disposable return air filters
  •  
  • Same footprint as installed Carrier 3-5 and 7.5-10 ton rooftops back to 1989,  reducing installation costs and time
  • Field convertible from vertical to horizontal airflow for slab mounting (sizes 04 to 14)
  • Provisions for thru-the-bottom power entry capability as standard
  • Single point gas and electric connections
  • Full perimeter base rail with built-in rigging adapters and fork truck slots
  • Dedicated vertical and horizontal airflow models available (factory option on size 17 to 28 units)
  • Scroll compressors with internal line-break overload protection
  • Carrier rooftop units have a 24-volt control circuit protected with resettable circuit breaker
  • Permanently lubricated evaporator-fan motor
  • Totally enclosed condenser motors with permanently lubricated bearings
  • Low pressure and high-pressure switch protection
  • Solid-state electronic direct spark ignition system and flame roll-out safety protector
  • Carrier rooftop units have a                                                                                                                                                                                                                                                                     10 years parts only electric heater
  • 5 years parts only compressor
  • One year parts only on all other parts
  • Extended warranty packages available